BUILDING STANDARDS
OCP Home

DIVISION 11 -- EQUIPMENT

11 12 00 PARKING CONTROL EQUIPMENT

  • This Standards Section should include University preferences on the following:
    1. Automatic barrier gates.
    2. Vehicle detectors.
    3. Traffic controllers.
    4. Ticket dispensers.
    5. Access control units.
    6. Central pay stations.
    7. Fee computers and printers
    8. Fee indicator.
    9. Exit terminals/verifiers.
    10. Parking facility management software.
    11. Lot full sign.
    12. Sirit antennas and processor boards (hands-free).
    13. Parking attendant booth.
    14. Fiberglass gate arms.
    15. Signage.
  • Parking control system shall be used for transient, monthly, and/or special-event parking.
    1. Transient Parking: Hourly rated parking, with fee paid while [entering]exiting.
    2. Monthly Parking: Monthly rated parking, with fee paid by the month and entry gained by access control card.
    3. Flat-Rate Parking: Unlimited-duration, daily parking, with fixed fee paid when entering and free exit.free gate entry and fixed fee amount paid while exiting.
    4. Special-Event Parking: Duration-of-event parking, with fee paid while entering with gates up or down.
  • Electrical System Roughing-in: Coordinate layout and installation of parking control equipment with connections to power supplies perimeter security system and security access control system.
  • Provide extra gate arms: Two (2) breakaway gate arms for each gate installed, complete with accessory components. We do not use the breakaway gate arms.
  • Subject to compliance with requirements, provide products by one of the following preferred manufacturers:
    1. Parking Control Equipment:
      1. Federal APD, Inc.
      2. Intellichip Technologies.
      3. Intertex Companies.
      4. Link Door Controls, Inc.
      5. Magnetic Automation Corporation.
      6. Operator Specialty Company, Inc.
      7. Parking Products, Inc.
      8. Sentex Systems.
      9. TCI Sales, Inc.
      10. Trafodata.
      11. Traf-Park Inc.
      12. WPS North America Inc.
      13. Zeag North America Inc.
    2. Traffic Controllers:
      1. Delta Scientific Corporation.
      2. Engineered Parking Systems, Inc.
      3. Intertex Companies.
      4. Parking Booth Company, Inc.
      5. Parking Products, Inc.
  • Bicycle Parking Equipment: Install secure bicycle racks in the parking lot within 200 yards of the entrance. There must be sufficient space for 50% of the building occupants to park bicycle.
     

11 13 00 LOADING DOCK EQUIPMENT

  • This Standards Section should include University preferences on the following:
    1. Dock bumpers.
    2. Dock levelers.
    3. Truck restraints.
    4. Dock shelters will be considered.
    5. Transparent-strip door curtains.
  • Warranty Period for Hydraulic System: One year from date of Substantial Completion.
  • Trench drain oil separators and dry pipe suppression systems will be coordinated with mechanical design.

11 18 23 REFRIGERATED DISPLAY EQUIPMENT

  • The university will not allow any refrigeration systems containing chlorofluorocarbons (CFCs).

11 22 00 VALUABLE MATERIAL STORAGE

  • 'Knox-Box Rapid Entry System' to be used for key lock boxes

11 52 13 PROJECTION SCREENS

  • Provide front-projection screens manufactured from mildew- and flame-resistant fabric of type indicated for each type of screen specified and complying with the following requirements:
    1. Matte-white viewing surface are preferred.
    2. Glass-beaded viewing surface are not allowed.
  • Coordinate locations of screen with reflected ceiling plan and emergency lighting.

11 82 26 WASTE COMPACTORS AND DESTRUCTORS

  • Size units for building size and bi-weekly pick-up.
  • Beginning at Substantial Completion, provide 12 months' full maintenance by skilled employees of Installer.
    1. Schedule regular surveillance and preventive maintenance visits at seven-day intervals for three months and at one-month intervals for nine months.
    2. Repair or replace worn or defective components; and lubricate, clean, and adjust equipment as required for proper equipment operation. Use replacement parts and maintenance supplies that were used in the manufacture and installation of the original equipment.
  • Manufacturers: Subject to compliance with requirements, provide products by one of the following:
    1. Accurate Industries.
    2. Bes-Pac, Inc.
    3. Chicago Trashpacker Corp.
    4. Galbreath, Inc.
    5. GPI/Harmony Enterprises, Inc.
    6. Holt Specialty Equipment, Inc.
    7. J. V. Manufacturing, Inc.
    8. Kohlman Engineering Corp.
    9. K-Pac Equipment Division/Krause Corp.
    10. Marathon Equipment Co.
    11. McClain Group/E-Z Pack.
    12. Precision Machinery Systems, Inc.
    13. SP Industries, Inc.
  • Vertical, Stationary Horizontal, Self-Contained Horizontal, Pivoting-Ram Compactors: Manufacturer's standard packaged units with components, options, and accessories needed to comply with requirements and provide complete functional systems.
  • Train Owner's maintenance personnel to use and maintain waste compactors. Demonstrate capacities, safety features, cleaning procedures, and proper methods for storing and handling raw and processed waste materials.