MEASUREMENT


1. A short term test using a Continuous Radon Monitor was conducted in a home. The result was 3.8 pCi/L.. What would be the proper response?
  No action necessary your home is safe.
  The level is so close to the action level you may want to test again in the future.
  Mitigate the home.
  Confirm the measurement with a long term test.

2. Radon Decay Products are measured in what units?
  pCi/L
  Bcq/m
  WL
  LLD

3. IDNS Protocols require that test devices be used in what areas of the home?
  Each level currently occupied.
  Each finished level.
  Each lowest structural area suitable for occupancy.
  Basement areas and rooms above a crawl space only.

4. Which of the following is true of Activated Charcoal Devices?
  Are biased toward the last 12 hours of the test period.
  Are true integrating devices
  Can be used for up to 90 days
  Are not affected by high humidity

5. What is minimum height distance above the floor for radon device place?
  30 inches
  6 feet
  1 foot
  20 inches

6. A homeowner calls you to mitigate their home. You discover that during the test period there were winds in excess of 30 miles per hour and 2 inches of rain. Your correct response would be:
  The test is invalid and the homeowner should arrange for a new test.
  Since most homes in that area have radon they should mitigate.
  Perform passive mitigation and re-test.
  Offer to re-test at no charge and if the levels are still 4pCi/l or above you will mitigate the home.

7. Alpha Track Devices are typically used for what type of testing?
  Short term testing.
  Houses with no basements.
  As diagnostic measurements to assist the mitigator.
  Long term testing.

8. A homeowner tells you that the results of 2 radon LS devices, placed side by side resulted in readings of 3.9pCi/L and 9.0 pCi/L. What is the correct response.
  The average is above 4pCi/L they should mitigate.
  The reading above 4 is greater than double the reading below 4pCi/L. Therefore the results are outside acceptable ranges. A re-test should be conducted.
  Someone must have tampered with the devices, a new test should be conducted.
  The reading above 4pCi/L indicates that there are high levels of radon and they should mitigate immediately.

9. A single short term test device may be used during a real estate transaction if it meets the following criteria:
  Integrate and record hourly or more frequently.
  Has the ability to disregard the first 4 hours.
  Can detect tampering.
  Measures temperature and humidity.

10. Side by side duplicate radon devices should be placed how far apart?
  10 inches.
  1 foot.
  3 feet.
  4 inches